Module common specification |
|||
---|---|---|---|
M03 ~ M09, M12, M15, M16, M18 ~ M23, OP1, OP2 |
M06, M11 module |
||
ㆍAC 220V module connection cable (3/4pin) : 1ea |
ㆍDC Voltage Meter : 1ea |
||
M04, M05, M07, M08, M12, OP2, OP6, OP8 module |
M07, M09, M22, M23 module |
||
ㆍDC Voltage Meter/DC Ampere Meter : each 1ea |
ㆍAC Voltage Meter/AC Ampere Meter : each 1ea |
||
Specifications |
|||
EXPERIMENTAL TABLE SET : 1ea |
|||
1) Table : 1ea - Aluminium Profile - Plate : 25mm (HPM) - Wheel : 4ea - Size : 1,600(W) x 800(D) x 820(H)mm - AC 220V Outlet : 2ea 2) Module case : 2ea - Opening and closing door with locking system 3) Frame to fix modules : 1ea - Aluminium Profile slot-board(25mm gap), Easy to fix and take off modules - Size : 900(W) x 305(D)mm 4) Module Rack - Aluminium Profile, 2-step module fixing - Up-down railway fixing - Size : 1,600(W) x 750(H)mm |
![]() |
||
AC POWER SOURCE MODULE (M01) | LIGHT SOURCE MODULE (M02) | ||
![]() |
1) Strong steel case, Silk-printed Front panel 2) Size : 250(W) x 309(D) x 120(H)mm 3) ELCB(AC220V/60Hz/15A/15mA) : 1ea 4) AC Inlet(Fuse, 5A) : 1ea 5) AC Power lamp : 1ea 6) Insulation earth connecting terminal : 1ea 7) AC 220V outlet(3/4pin) : 1ea 8) AC 220V module connecting cable(3/4pin) : 1ea |
![]() |
1) Output : 300W 2) Power : 220V 50/60Hz 3) Halogen lamp 4) Heat-resisting glass 5) Dimming control : 0~100% 6) Angle control function |
PHOTOVOLTAIC CELL MODULE-A (M03) | PHOTOVOLTAIC CELL MODULE-B (M04) | ||
![]() |
1) Strong steel case, silk-printed front panel |
![]() |
1) Strong steel case, silk-printed front panel |
HYBRID CONTROLLER MODULE (M05) | BATTERY MODULE (M06) | ||
![]() |
1) Strong steel case, silk-printed front panel 2) Size : 380(W) x 309(H) x 120(D) mm 3) Charging controller - Normal voltage : 12V - Boost voltage : 13.5V (25℃), 2hr - Equalization voltage : 14.8V (25℃), 2hr - Float voltage : 13.7V (25℃) - Low-voltage defense (LVD) : 11.4~11.9V (controlled by charging status) 11.0V (controlled by voltage) - Load re-connecting voltage : 12.8V - Temperature compensation : -4mV/Cell*k - Maximum input current (Solar panel) : 5/8/10/15/20A - Maximum load current (Load) : 5/8/10/15/20A 4) DC voltage meter/ DC ampere meter : each 1ea 5) PV output terminal : 1set 6) Battery input terminal (4mm) : 1set 7) Output terminal (DC load, inverter, 4mm) : each 1set |
![]() |
1) Strong steel case, silk-printed front panel 2) Size: 380(W) x 309(H) x 120(D) mm 3) Battery (12V, 7AH): 2ea 4) Battery output terminal (4mm): 1set 5) DC Voltage meter: 1ea - Maximum measuring input: DC500V, DC5A, AC5A - Maximum display range: -1999 ~ 9999 - Hi/Low scale function - AC frequency measurement (0.1~9999Hz) - Communication: RS485 - Voltage/Current input terminal (4mm) : each 1set |
STAND-ALONE INVERTER MODULE (M07) | DC LOAD MODULE (M08) | ||
![]() |
1) Strong steel case, silk-printed front panel |
![]() |
1) Strong steel case, silk-printed front panel |
AC LOAD MODULE (M09) | TIME CONTROLLER MODULE (M10) | ||
![]() |
1) Strong steel case, silk-printed front panel |
![]() |
1) Strong steel case, silk-printed front panel 2) Size : 380(W) x 309(H) x 120(D) mm 3) AC Inlet (with fuse) : 1ea 4) ELCB (AC220V/60Hz/15A/15mA) : 1ea 5) AC outlet (AC220V) : 1ea 6) Electronic security automatic blinking device : 1ea - LCD display - Input keypad : 4ea - Power and output lamp : each 1ea - Setting function: Present time, date, light-on time, light-off time |
AUTOMATIC CHARGER MODULE (M11) | WIND GENERATOR MODULE (M12) | ||
![]() |
1) Strong steel case, silk-printed front panel 2) Size : 380(W) x 309(H) x 120(D) mm 3) Indication lamp : Battery full-charged, battery charging status 4) Charging voltage selection : 13.4V, 14.4V 5) Charging current : Rated 10A 6) Output short-cut protection function 7) High effectiveness automatic function 8) Battery reverse polarity connecting protection function : DC output block function 9) AC Inlet (with fuse) : 1ea 10) DC output terminal (4mm) : 1set 11) Insulation earth connecting terminal : 1ea |
![]() |
1) Strong steel case, silk-printed front panel |
PHOTOVOLTAIC CELL CONNECTION MODULE (M13) |
HYDROGEN LOAD & DC/DC CONVERTER MODULE (M15) |
||
![]() |
1) Strong steel case, silk-printed front panel |
A. DC Voltage Meter : 2ea / DC Digital Ampere Meter : 1ea |
|
HYDROGEN GENERATOR MODULE (M16) |
MULTI TYPE BATTERY BANK MODULE (M18) |
||
A. Electrolyzer : 1ea |
A. Battery(12V, 7AH) : 3ea |
||
MULTI TYPE CHARGING CONTROLLER MODULE (M19) |
MULTI TYPE GRID CONNECTED INVERTER MODULE (M20) |
||
A. Charging Controller : 3ea |
A. GRID CONNECTED INVERTER : 3ea |
||
DISTRIBUTED POWER CONTROL MODULE (M21) |
MART HOME APPLIANCE LOAD MODULE (M22) |
||
A. The commercial power grid and Regional power generation(Renewable energy) power connection function(Input channel) |
A. Smart home appliance 1 : Lighting (LED lamp) |
||
AC METER MODULE (M23) |
SMART GRID MONITOR MODULE (OP1) |
||
A. Digital AC power meter : 1ea |
1) Strong steel case, silk-printed front panel |
||
VIRTUAL PHOTOVOLTAIC ARRAY MODULE (OP2) |
GRID CONNECTED INVERTER MODULE (OP3) |
||
![]() |
1) Strong steel case, silk-printed front panel |
![]() |
1) Strong steel case, silk-printed front panel |
ADJUSTABLE ANGLE OF SOLAR MODULE (OP4) |
ELECTRICITY METER MODULE (OP5) |
||
![]() |
1) PV Cell |
![]() |
1) 1phase 2wire(1P2W) 2) Load capacity : under 220V, 6.6kW 3) maximum current/ test current : 30(10A) 4) voltage : 220V, 60Hz 5) power loss : 3.7 / 0.42(VA) 6) error : ±2% 7) size : 250(W) x 309(H) x 120(D)mm |
MPPT MODULE (OP6) |
DC METER MODULE (OP8) |
||
![]() |
1) Schematic graphical representation of the actual maximum power point tracking 2) Solar cell voltage command self-tracking feature, depending on fluctuations occur 3) DC Ampere Meter : 2ea 4) DC Voltage Meter : 2ea 5) DC Watt Meter : 2ea 6) Solar Cell Input : 2ea 7) DC Load (25W) : 2ea 8) V-P Characteristic Curve Graphic : 1ea 9) V-I Characteristic Curve Graphic : 1ea 10) Size : 380(W)x 309(H)x 120(D)mm |
![]() |
1) DC Voltage Meter : 1ea 2) DC Ampere Meter : 1ea 3) Voltage Input port : 2ea 4) Current Input port : 2ea 5) Size : 124(W) x 118(H)mm |
ANALOG WATT HOUR METER MODULE (OP9) |
300W GRID CONNECTED INVERTER MODULE (OP10) |
||
![]() |
A. Real-time consumption monitoring according to the generation amount |
![]() |
A. Rated input : 10.8V~30V |
Accessories
ㆍUser's manual : 1ea
ㆍConnection cable(Insulation type) : 1set
ㆍModule power connection cable(Round type 3/4pin) : 1set
ㆍRS485 Communication cable(For module connection) : 1set
ㆍPower cable : 1set
ㆍExperimental manual : 1ea
ㆍBasic principles of solar and wind power generation
ㆍPrinciples and system of solar and wind power generation
ㆍCharacteristics of power generation by the quantity of light
ㆍElectrical characteristics test(open circuit voltage, short-circuit current) by solar module
ㆍI-V, P-V characteristics test by angle of incidence of solar module
ㆍI-V, P-V characteristics test by distance of solar module
ㆍI-V, P-V characteristics test by temperature characteristics of solar module
ㆍI-V, P-V characteristics test by irradiance of solar module
ㆍV-I characteristics and load test of solar generation according to the series/parallel wiring of solar cells
ㆍCharge/discharge battery experiment by charge controller
ㆍPower converting by stand-alone inverter
ㆍPower conversion experiment by grid inverter
ㆍVoltage and Current value Smart Grid monitoring test by generations
ㆍStreetlight control experiment according sunrise and sunset times
ㆍMPPT control test
ㆍPrinciple and gird experiment of Wind power generation
ㆍCharacteristic experiment according to the rotational speed and load of Wind power generator
ㆍCharacteristic curves of Hydrogen electrolysis
ㆍFaraday efficiency and energy efficiency of electrolysis
ㆍPrinciple and gird experiment of Hydrogen fuel cell generation
ㆍCharacteristic curves for Fuel cell which connected by series/parallel
ㆍCharacteristic experiment for the power generation and load of Hydrogen fuel cells
ㆍSolar/Wind hybrid power generation experiment
ㆍSolar/Hydrogen hybrid power generation experiment
ㆍWind/Hydrogen hybrid power generation experiment
ㆍSolar/Wind/Hydrogen hybrid power generation experiment
ㆍData measurement management experiment using RS-485 communication port
ㆍVoltage and Current values Smart grid monitoring experiment by generations
ㆍDistributed Power Management Experiment using Smart grid