Electrical Sequence Training System CPS-SQ38
Home > Product Introduction > Edu. - ElectricityㆍElectronics > Electrical Sequence Training System CPS-SQ38
Electrical Sequence Training System
CPS-SQ38
* Electric sequence circuit control
* Sequence circuit by PLC control
* Relay control sequence
* Understanding and control practice of magnetic
contactor, timer, electric switch circuits
* Sequence control by Proximity sensor
* Sequence circuit connection experiment
* Earth Leakage current Circuit Breaker (ELCB) practice
  • Feature/Function
  • Configuration/Specifications
  • Options/Accessories
Configuration/Specifications
1) Source: Three-Phase AC 220V
2) ELCB(Earth Leakage current Circuit Breaker) : 1ea
- Rated Current : 30A
- Rated Voltage : 3ø AC 220V/60Hz
- Rated Residual Current, I△n : 30mA
- Residual Non-Operating Current: 15mA
- Residual Current Off-Time at I△n : ≤ 0.03sec
3) MC; Magnetic Contactor(5a2b) : 3ea
- Coil Voltage/Current: AC 220V 60Hz / 41mA
- AC3 Ratings/IEC60947-4 : AC 240V/4.5kW/18A
- Auxiliary Contact : AC 240V/3A
4) Auxiliary Contactor(1a3b) : 3ea
- Coil Voltage/Current : AC 220V 60Hz
- Rated Current : AC 240V/3A (Inductive Load)
5) EOCR(Electronic Over Current Relay, 1/2HP) : 1ea
- Number of internal CT (Sensor) : 3CT (Tunnel Type)
- Current setting : 0.3 ~ 1.5A
- Trip Time Setting : 0 ~ 30sec
- Relay Control Voltage : AC 100~260V/60Hz
- Auxiliary Contact: AC 250V/3A (Resistive Load)
6) Relay : 4ea
- Coil Voltage/Current : AC 220V 60Hz / 11.5mA
- Contacting Time : ≤ 25ms
- Rated Current : AC 220V/7A(R Load), AC 220V/5A(L Load)
7) Time Relay(30sec) : 2ea
- Operating Type : On Delay
- Rated Power : AC 220V/60Hz/2.5VA
- Output Contact Capacity: AC 220V/1.5A (R Load)
8) Flicker Time Relay(6sec) : 1ea
- Operating Type : On Start
- Rated Power : AC 220V/60Hz/2.5VA
- Output Contact Capacity : AC 220V/2.5A (R Load)
9) Counter : 1ea
- Power Source : AC 100~240V/60Hz
- Output Contact Capacity : AC 250V/3A (R Load)
10) Proximity Sensor : 1ea
- Operating Type : NPN, NO
- Detecting Distance : 8mm ±10%
- Standard Detecting Target : Iron(25×25×1mm)
- Operating Voltage : DC24V (DC10~30V)
11) Lamp(Green:2ea, Red:2ea) : 4ea
- Operating Voltage: AC 220V
- Lamp : DC 6.3V
12) Buzzer : 1ea
- Operating Voltage : AC 220V/4VA
13) Push Button Switch(Non-Lock, Green:2ea, Red:2ea) : 4ea
- Output Contact Capacity : AC 250V/6A, 1a1b
14) Toggle Switch : 4ea
- Output Contact Capacity : AC 125V/10A, AC 250V/6A, 1a1b
15) Emergency Switch : 1ea
- Output Contact Capacity : AC 250V/6A, 1a1b
16) Three-Phase Induction Motor : 1ea
- Operating Voltage : 3ø AC 220V/380V/25watt
- Motor Type : 4pole, Squirrel Cage Rotor, Y-Δ Starting
17) Fuse Holder & Fuse (5A) : 2ea
18) DC Power Output : 3set
- Output : DC 24V/1A(Fuse)
19) Dimension : 1,075(W) × 350(D) × 660(H)mm